Basic Info.
After-sales Service
on Line Support
Lubrication Style
Oil-free
Cooling System
Water Cooling
Cylinder Position
Horizontal
Structure Type
Closed Type
Installation Type
Stationary Type
Type
Twin-Screw Compressor
Transport Package
Wooden Box
Specification
5040*1650*2100
Product Description
Product Description
THE ELEMENT
The compressor element's efficiency and tightness are ensured by its unique profile design.
The aviation impeller coating assures long-term performance.
Oil tank and speed-increasing gearbox are integrated.
Great efficiency, energy savings, and high reliability are all features of the built-in oil pump.
THE AIR END
The compressor air end has a unique profile design that ensures its efficiency and tightness.
The aviation impeller coating assures long-term performance.
The material for the rotor is forged steel, which has high strength and hardness.
Cooling jackets are used on all series of air ends.
Reusable seal made of high-quality metal.
THE ROTOR
Cooling sleeves guarantee that rotor clearance is kept to a bare small at all times.
Boost efficiency and dependability.
A high-efficiency shaft seal decreases wear and eliminate the possibility of oil leakage.
THE COOLER
High heat exchange efficiency, thanks to an integrated water flow design.
Switching is simple with the heat recovery module.
Flow channel built-in, easy to use, and dependable.
THE AIR FILTER
A high-quality intake filter ensures a high level of filtering.
High energy efficiency and process reliability.
Long service life and intervals between maintenance.
THE INTELLIGENT CONTROLLER
The sophisticated control system allows for simultaneous compressor and after-treatment control.
No maintenance is necessary because the hardware and software are designed to be reliable. Multiple local and remote communication options are supported. A thorough examination of the unit's operational status and historical data.
Product Parameters
Model | Maximum Working Pressure | Capacity(FAD)* | Installed Motor Power | Cooling Method | Noise Level | Air Outlet Pipe Diameter | Dimension | Weight |
50hz |
bar(g) | psig | m3/min | cfm | kw | hp | dB(A) | L | W | H | kg |
RF37-7VSD A(W) | 7 | 102 | 3.0-6.5 | 105.9-229.5 | 37 | 50 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1850 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 1950 |
RF37-8VSD A(W) | 8 | 116 | 2.8--6.4 | 98.8-226 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1850 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 1950 |
RF37-10VSD A(W) | 10 | 145 | 2.6-6.3 | 91.8-222.4 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1850 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 1950 |
RF45-7VSD A(W) | 7 | 102 | 4.5-7.7 | 158.9-271.8 | 45 | 60 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 |
RF45-8VSD A(W) | 8 | 116 | 4.0-6.5 | 141.2-229.5 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 |
RF45-10VSD A(W) | 10 | 145 | 3.5-6.8 | 123.6-240.1 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 |
RF55-7VSD A(W) | 7 | 102 | 5.0-9.6 | 176.5-339 | 55 | 75 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 |
RF55-8VSD A(W) | 8 | 116 | 4.5-8.8 | 158.9-310.7 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 |
RF55-10VSD A(W) | 10 | 145 | 3.5-7.7 | 123.6-271.9 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 1900 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 |
RF75-7VSD A(W) | 7 | 102 | 5.5-13.5 | 194.2-476.7 | 75 | 100 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 |
RF75-8VSD A(W) | 8 | 116 | 4.5-13.3 | 158.9-469.6 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 |
RF75-10VSD A(W) | 10 | 145 | 4.4-12.1 | 155.3-427.3 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2100 |
RF90-7VSD A(W) | 7 | 102 | 5.2-16.2 | 183.6-572 | 90 | 120 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2200 |
RF90-8VSD A(W) | 8 | 116 | 4.5-15.6 | 158.9-550.9 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2200 |
RF90-10VSD A(W) | 10 | 145 | 4.4-14.2 | 155.3-501.4 | Air Cooling | 70 | DN50 | 2160 | 1450 | 2200 | 2000 |
Water Cooling | 63 | DN80 | 2180 | 1450 | 2200 | 2200 |
RF110-7VSD A(W) | 7 | 102 | 10.2-19.5 | 360.2-688.6 | 110 | 150 | Air Cooling | 69 | DN80 | 4050 | 1650 | 2000 | 3700 |
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2700 |
RF110-8VSD A(W) | 8 | 116 | 9.3-19.2 | 328.4-678 | Air Cooling | 69 | DN80 | 4050 | 1650 | 2000 | 3700 |
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2700 |
RF110-10VSD A(W) | 10 | 145 | 8.5-17.5 | 300.1-618 | Air Cooling | 69 | DN80 | 4050 | 1650 | 2000 | 3700 |
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2700 |
RF132-7VSD A(W) | 7 | 102 | 10.8-23.5 | 381.3-829.8 | 132 | 175 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3700 |
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2800 |
RF132-8VSD A(W) | 8 | 116 | 10.4-22.8 | 367.2-805.1 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3700 |
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2800 |
RF132-10VSD A(W) | 10 | 145 | 9.9-20.5 | 349.6-723.9 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3700 |
Water Cooling | 67 | DN80 | 2550 | 1650 | 2000 | 2800 |
RF145-7VSD A(W) | 7 | 102 | 11.2-23.9 | 395.5-844 | 145 | 195 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3900 |
Water Cooling | 68 | DN80 | 2550 | 1650 | 2000 | 3000 |
RF145-8VSD A(W) | 8 | 116 | 10.2-22.1 | 360.2-780.4 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3900 |
Water Cooling | 68 | DN80 | 2550 | 1650 | 2000 | 3000 |
RF145-10VSD A(W) | 10 | 145 | 9.8-20.5 | 346.0-723.9 | Air Cooling | 70 | DN80 | 4050 | 1650 | 2000 | 3900 |
Water Cooling | 68 | DN80 | 2550 | 1650 | 2000 | 3000 |
RF160-7VSD A(W) | 7 | 102 | 12.1-28.5 | 427.3-1006.4 | 160 | 215 | Air Cooling | 74 | DN80 | 5040 | 1650 | 2100 | 5400 |
Water Cooling | 72 | DN80 | 3100 | 1650 | 2000 | 4000 |
RF160-8VSD A(W) | 8 | 116 | 11.6-26.4 | 409.6-932.3 | Air Cooling | 74 | DN80 | 5040 | 1650 | 2100 | 5400 |
Water Cooling | 72 | DN80 | 3100 | 1650 | 2000 | 4000 |
RF160-10VSD A(W) | 10 | 145 | 9.9-24.5 | 349.6-865.2 | Air Cooling | 74 | DN80 | 5040 | 1650 | 2100 | 5400 |
Water Cooling | 72 | DN80 | 3100 | 1650 | 2000 | 4000 |
RF200-7VSD A(W) | 7 | 102 | 16.5-36.1 | 582.6-1274.8 | 200 | 270 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5600 |
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4200 |
RF200-8VSD A(W) | 8 | 116 | 15.4-33.9 | 543.8-1197.1 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5600 |
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4200 |
RF200-10VSD A(W) | 10 | 145 | 15.0-30.8 | 529.7-1087.6 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5600 |
Water Cooling | 67 | DN80 | 3100 | 1650 | 2000 | 4200 |
RF250-7VSD A(W) | 7 | 102 | 21.1-45.2 | 745.1-1596.2 | 250 | 350 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5800 |
Water Cooling | 74 | DN80 | 3100 | 1650 | 2000 | 4300 |
RF250-8VSD A(W) | 8 | 116 | 19.2-43.4 | 678.0-1532.6 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5800 |
Water Cooling | 74 | DN80 | 3100 | 1650 | 2000 | 4300 |
RF250-10VSD A(W) | 10 | 145 | 18.5-38.8 | 653.3-1370.2 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5800 |
Water Cooling | 74 | DN80 | 3100 | 1650 | 2000 | 4300 |
RF275-7VSD A(W) | 7 | 102 | 22.2-46.8 | 783.9-1652.7 | 275 | 370 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5900 |
Water Cooling | 74 | DN80 | 3100 | 1650 | 2000 | 4400 |
RF275-8VSD A(W) | 8 | 116 | 21.3-43.5 | 752.2-1536.1 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5900 |
Water Cooling | 74 | DN80 | 3100 | 1650 | 2000 | 4400 |
RF275-10VSD A(W) | 10 | 145 | 20.1-41.5 | 709.8-1465.5 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5900 |
Water Cooling | 74 | DN80 | 3100 | 1650 | 2000 | 4400 |
RF315-7VSD A(W) | 7 | 102 | 25.0-53.0 | 882.8-1871.6 | 315 | 420 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5800 |
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4400 |
RF315-8VSD A(W) | 8 | 116 | 24.0-51.5 | 847.5-1818.7 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5800 |
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4400 |
RF315-10VSD A(W) | 10 | 145 | 23.0-49.5 | 812.2-1748 | Air Cooling | 76 | DN80 | 5040 | 1650 | 2100 | 5800 |
Water Cooling | 65 | DN80 | 3100 | 1650 | 2000 | 4400 |
Detailed Photos
Address:
Floor1, Building 2, No 599 Hongan Road, Zhujing Town, Jinshan District, Shanghai
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Industrial Equipment & Components
Management System Certification:
ISO 9001
Company Introduction:
Shanghai Runningway Machinery Co., Ltd., a compressed air system solution provider linked with American Runningway Group Inc (registered trademark RUNNINGWAY), focused on 5G smart air compressor technology development, manufacturing, sales, and service. A number of technical patents and numerous authorized certificates have been obtained.
The company′s main products include the 5G intelligent oil-free scroll air compressor, 5G intelligent oil-free dry screw air compressor, 5G intelligent oil-free water-lubricated screw air compressor, medical silent, and box-type oil-free piston air compressor, 5G oil-blooded screw air compressor, and others, which are exported to Europe, North America, the Middle East, Southeast Asia, and other countries and regions.
Our objective is to serve consumers and add value. China benefits from American technology.
With 5G Internet of Things, AI intelligent control, energy savings and environmental protection, and a green oil-free compressed air system, a new era of 5G intelligent air compressors has begun.
We can supply you with the most dependable service in the sectors of oil-free and oil-injected screw air compressors, centrifugal air compressors, air-bearing centrifugal blowers, and screw blowers.